Project Description

Low-energy Light Industrial units and Offices for North Tipperary Green Enterprise Park Ltd.

  • Less than 5 air changes per hour airtightness, half the required maximum air leakage for this type of building
  • composite wall and roof product, with better than minimum U-values
  • Naturally ventilated to eliminate sick-building syndrome
  • Naturally day-lit with a double height entrance atrium
  • Well insulated foundations, vertical perimeter insulation around the entire footprint and under floor heating
  • GGBS low embodied CO2 concrete foundations
  • Marmoleum floors

enterprise industrial unit